It is the length from the support of the rope to the center of gravity of the swinging. More Details >>
- No:20934
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
By inputting the rope length, the speed command is sent to suppress a swinging. More Details >>
- No:20935
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Waiting time at the instantaneous power failure
The count is started from the power failure. The count is started after the power restoration or reset release when the power failure period is too long, or ... More Details >>
- No:20939
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The internal transistor of the HC2 stops by turning on the SOF signal and stopping the converter. As a result, regenerative driving is not performed. However... More Details >>
- No:20941
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Because the internal reset processing is performed when the power supply is turned OFF, the fault state cannot be held. The details of the faults are saved i... More Details >>
- No:20942
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
For output signals, up to 10 points (RXn2 to RXB) can be assigned. It is possible if the number of the importing signal points are within this range. More Details >>
- No:20943
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
It is because the CC-Link monitor is designed to hold the value at an error occurrence. More Details >>
- No:20946
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
A1: Blue, A2: White (transparent) More Details >>
- No:20947
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Sampling time of FR Configurator2
It depends on the mask count. It is approximately 0.125 [ms] (mask count: 1) to 20 [ms] (mask count: 30). More Details >>
- No:20950
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Set 3 kg (intermediate value) for the load weight 1 to 5 kg. More Details >>
- No:20953
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
61-70 of Total 1368