FAQ within [ MELSEC-Q Series ]
-
Turning OFF the power with the battery error occurring
It deletes the error history. More Details >>
- No:22545
- Release Date:2018/09/03 17:28
-
Difference between C Controller module and programmable controller CPU module
- C Controller module: Programs are created using C and C++ languages. The programs run based on each task and parallel processing of multiple tasks base... More Details >>
- No:22542
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:05
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
-
Hardware setting for using Q series extension base units
You need to set the number of extension base units with the connector for setting the number of extension base units.For details, refer to the following.SH-0... More Details >>
- No:22721
- Release Date:2018/09/03 17:29
-
A/D conversions performed by Q64AD/Q68ADV/Q68ADI
(1) Sampling processing - Without the temperature drift compensation function Processing time = Number of channels usedx 80 (us/1 channel) - With the t... More Details >>
- No:22705
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:34
-
Compatibility between the A series modules and Q series modules
When an ACPU module is replaced with a QCPU module, programs for the ACPU module can be used by changing the PLC type in GX Developer. However, the programs ... More Details >>
- No:22696
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:21
-
Speeds of access to file registers
If file registers are registered in the standard RAM and "R" is specified by an instruction, the processing time is the same as is the case with the internal... More Details >>
- No:22688
- Release Date:2018/09/03 17:29
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18
-
Q series device data held in the case of a power failure
The data in the devices assigned to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> [Device Setting] window) is held when a pow... More Details >>
- No:22638
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:37
-
MODBUS(R) interface module's involvement in master and slave stations
Intelligent function module settings allow them to be set in both master and slave stations. More Details >>
- No:22637
- Release Date:2018/09/03 17:29