Data collection with FX programmable controller
Data stored in the programmable controller can be saved to a CF card usinga FX3U-CF-ADP CF card special adapter for the FX3U/FX3UC series. More Details >>
- No:24936
- Release Date:2019/04/18 14:24
-
Extension blocks and units that can be used in the FX3U series
The operation is not guaranteed. Please select the extension blocks and units from FX2N series. More Details >>
- No:24935
- Release Date:2019/04/18 14:24
-
Connecting special adapters to FX3U series
Anexpansion board is required. (However, it is not required when connecting only the special high-speed I/O adapter.) More Details >>
- No:24934
- Release Date:2019/04/18 14:23
-
Overwriting a current value with the high-speed counter comparison instruction
The output contact is activated according to the change of the current value register along with the counting input. Therefore, the value changed by executin... More Details >>
- No:24931
- Release Date:2019/04/17 11:43
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3U series. *The FX3U-ENET-ADP is a communication special adapter and o... More Details >>
- No:24912
- Release Date:2019/04/17 11:39
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34