Monitor code of CC-Link communication
The monitor with the code H01 switches by changing Pr.37 and Pr.144. More Details >>
- No:21236
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote register when instruction code execution request is issued at CC-Link communication
The value "0" is stored. More Details >>
- No:21234
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
PID control of CC-Link communication
When performing the PID control by CC-Link communication, the X14 signal is disabled. More Details >>
- No:21233
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Speed command by CC-Link communication
It is not possible when the speed command is communication. More Details >>
- No:21232
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Instruction code execution request of CC-Link communication
Only one instruction is executed. The instruction to be executed is not fixed. More Details >>
- No:21231
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Checking bit state by CC-Link communication
Because the H0F monitor only observes the ON/OFF of the hardware, it cannot be checked. More Details >>
- No:21230
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is tilted to wire the cable easily. More Details >>
- No:21228
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Inverter installation when using the FR-A7NCE
Normally, the required space for A700 3.7K or lower is 1 cm. However, when using CC-Link IE, it needs to be separated for 5 cm or more to pass the cable. More Details >>
- No:21227
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Noise effect of CC-Link IE communication
The same test as CC-Link is performed, and we confirmed no problem. More Details >>
- No:21226
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL