Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
Is the number of writing times of the parameter memory limited?
1. The limit of the parameter writing is 100,000 times. 2. Parameter error occurs. Since the data in the ROM may be broken, the inverter may become unavailab... More Details >>
- No:21385
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The instantaneous power failure error occurs when the power is turned ON instantaneously (within 100 ms) after the power is turned OFF. When the motor is coa... More Details >>
- No:21388
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasure against the harmful effect on model selection and other devices
Harmful elements that may affect other devices through the input side of the inverter include noise and harmonics. Harmonics can be reduced by inserting the ... More Details >>
- No:21396
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
When measuring current, if you open the output side while current is flowing on the input side, high voltage is induced and dielectric breakdown may occur wi... More Details >>
- No:21399
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Priority of multi-speed setting and frequency setting signals
For frequency setting, multi-speed setting is prioritized over current input. Therefore, when the multi-speed signal is input, the inverter switch to multi-s... More Details >>
- No:21400
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Although you can connect an analog or digital indicator to the terminal FM, use an analog indicator since the wiring length is long. (The maximum wiring leng... More Details >>
- No:21415
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
It is considered that communication settings between the inverter and personal computer do not match. Check if settings such as communication rate and stop b... More Details >>
- No:21431
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Since the heat sink and fan are not waterproof, you need to enclose them so that they are not exposed to the spray of water. If you use the inverter (heat si... More Details >>
- No:21433
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Can I use a motor of which capacity is larger than the inverter capacity?
Even when the actual load (torque) is half of the motor capacity, the current output from the inverter to the motor is not reduced to the half. Therefore, it... More Details >>
- No:21442