FAQ
FAQAbout Products
FAQ
Keyword Search
Low-voltage Power Distribution Products
FAQ within [ Low-voltage Power Distribution Products ]
-
Rated current and continuous current
The rated current is standard value for continuous current, short time delay current and instantaneous current. Continuous current is non-breaking current (c... More Details >>
- No:22371
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
High-speed residual operate CBR
It is Earth Leakage Circuit Breaker that the earth leakage trip operating time at the rated residual operating current (IΔn) is within 0.1 sec, and the earth... More Details >>
- No:22380
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Transformers, wires and welded materials may be damaged if an abnormal energization occurs exceeding the energization cycles that are set for the inverter we... More Details >>
- No:22393
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
Short circuit current calculation software
You can calculate that with MELSHORT 2 (Free of charge). More Details >>
- No:22394
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
"a contact" is normally opened contact, and It is also called "NO (Normally Opened) contact". More Details >>
- No:22410
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
About Low-voltage Power Distribution Products
Since it is necessary to energize the pole containing a heater element of athermal load relay, you need to connect it to both side of 3 poles(Between 1/L1-2/... More Details >>
- No:23249
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
DIN rail can be added to 5A frame and 8A frame of US-N* type asstandard and 20A frame as special product. Type name : US-N5SS(TE),US-N5SS(TE), US-N20(TE)RMMo... More Details >>
- No:23306
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to operate it by using two US-N* type. For the interlock ofboth US-N* type, UA-RE type reversible unit is used. More Details >>
- No:23375
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
As to exchange the LCD (ME96SS series).
The LCD cannot be exchanged. More Details >>
- No:22145
- Release Date:2018/08/27 16:41
- Update:2020/04/10 14:05
- Category: Electrical Indicators
241-250 of Total 323