It may not trip a fault current or degrade insulation after tripping. When you connect the device in reverse, you must select a reverse-connectable model. More Details >>
- No:22345
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
We don't provide the earth leakage circuit beaker for PV power. Please use a general leakage circuit breaker. However, you need to select a reverse-connectab... More Details >>
- No:22348
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
It is the maximum voltage which meets the performance criteria for the rated operational voltage. More Details >>
- No:22367
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
The control power supply of the earth leakage detection circuit is taken from the inside of Earth Leakage Circuit Breaker. If used on the secondary side of t... More Details >>
- No:22372
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Operating characteristics described in our catalog (if there is no "Note" particularly) mean operating time when it starts to carry current from the conditio... More Details >>
- No:22374
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It means that it does not interfere with tripping operation even if a handle is held at "ON" position. (It trips when an overcurrent flows even if a handle i... More Details >>
- No:22378
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
No, you must not use 2-pole circuit breaker as 1-pole circuit breaker (series connection as only single phase ). If using it as 1-pole circuit breaker, these... More Details >>
- No:22382
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
All our products are compliant with CCC (China Compulsory Certification). More Details >>
- No:22386
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
Default setting from the factory
The knob of the sensitivity current selector is set to the maximum value when shipping in order to prevent unwanted earth leakage tripping when Earth Leakage... More Details >>
- No:22391
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
AL/AX direct connection to PLC
It is necessary to use AL and AX switches that are suitable for the specification of PLC input unit. Generally AL and AX switch for micro-load are used for i... More Details >>
- No:22398
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
71-80 of Total 323