  • Connection of the FR-HEL

    Yes. More Details >>

    • No:20987
    • Release Date:2018/08/22 16:25
  • FR-ASF

    The FR-ASF may be damaged due to the surge voltage. More Details >>

    • No:20989
    • Release Date:2018/08/22 16:25
  • FR-HAL

    The UL94V-0 flammability standard is satisfied. More Details >>

    • No:20990
    • Release Date:2018/08/22 16:25
  • FR-LU08

    It is general type button battery (CR1216 × 1). More Details >>

    • No:21088
    • Release Date:2018/08/22 16:25
  • Line noise filter

    Yes. However, it is difficult to wind the twisted wires because they are thick. More Details >>

    • No:21128
    • Release Date:2018/08/22 16:26
  • FR-BMF

    The inverter may be broken due to the temperature rise of the internal parts. More Details >>

    • No:21140
    • Release Date:2018/08/22 16:26
  • FR-HC2

    Three phases are measured with the CT. The accuracy is ±10 % which is same as the inverter output current. More Details >>

    • No:21145
    • Release Date:2018/08/22 16:26
  • FR-HC2

    The power of MC1 is supplied from the terminals across R2 and S2 of the outside box. Either phase of R2 or S2 may be lost. More Details >>

    • No:21146
    • Release Date:2018/08/22 16:26
  • FR-HC2

    It controls the charging current immediately after the power is ON. (as a resistor for charging current limit circuit) More Details >>

    • No:21150
    • Release Date:2018/08/22 16:26
  • FR-HC2

    It prevents high-frequency current due to switching that is output by the FR-HC2 from being flown into the power supply system as a filter. More Details >>

    • No:21151