FAQ within [ Plug-in Options ]

21-30 of Total 30

prev 3 / 3page next
  • Plug-in options

    Use the plug-in option dedicated for the FR-A200EXECLLENT. The plug-in option for the FR-A200EXECLLENT cannot be used with the FR-A200. To avoid installing a... More Details >>

    • No:21634
    • Release Date:2018/08/22 16:28
  • Digital input and maximum frequency

    1. Pr.1 and 18 limit the output to 120 Hz. Use Pr.18 to change the maximum frequency. 2. If you want to output the binary input as is, setting Pr.304 = 1 (Bi... More Details >>

    • No:22098
    • Release Date:2018/08/22 16:30
  • FR-A8AZ

    Not available. When using the motor thermistor function, use the dedicated motor V5RU with a thermistor. More Details >>

    • No:21003
    • Release Date:2018/08/22 16:25
  • 12-bit digital input

    You can set both the BCD code and binary code inputs within the range from 0 to 400 Hz.You can set the bias and gain in 0.01 Hz units.For BCD input, when the... More Details >>

    • No:21945
    • Release Date:2018/08/22 16:30
  • Plug-in options

    The conventional plug-in option (FR-A7[][]) cannot be used. Use the dedicated plug-in option (FR-A8[][]). More Details >>

    • No:21114
    • Release Date:2018/08/22 16:25
  • FR-A800 and Ethernet IP communication

    Yes. the options support it. By connecting the following communication option (built-in circuit board) manufactured and sold by HMS to the FR-A800 series, th... More Details >>

    • No:20823
    • Release Date:2018/08/22 16:24
  • Parameter writing via CC-Link

    Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>

    • No:21976
    • Release Date:2018/08/22 16:30
  • FR-A8AX/A8AY

    For the FR-A700/F700, the hook is cut off for the wiring due to restrictions on the structure. These restrictions are eliminated for the FR-A800/F800. More Details >>

    • No:21051
    • Release Date:2018/08/22 16:25
  • Resetting inverter after restoring from power failure

    When the programmable controller power is turned OFF while the inverter is in the PLC link operation mode, a communication error occurs and the inverter trip... More Details >>

    • No:21417
    • Release Date:2018/08/22 16:27
  • Error of the communication option

    E.OP1 indicates the communication line error. E.1 indicates a hardware fault of the communication option. (It is judged as the hardware fault when the commun... More Details >>

    • No:20805
    • Release Date:2018/08/22 16:24