Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-A800 ]

131-140 of Total 144

prev 14 / 15page next
  • SW1DND-FRC2 (FR Configurator2)

    Check the setting value of Pr.414 (PLC function operation selection) and if the initial value: 0 (PLC function disabled) is set, set "1" or "2" and enable th... More Details >>

    • No:21080
    • Release Date:2018/08/22 16:25
  • Plug-in options

    Up to three plug-in options can be mounted. More Details >>

    • No:21093
    • Release Date:2018/08/22 16:25
  • EMC filter

    A capacitive filter and common mode choke are built in. (A common mode choke is built in only for the 55K or lower.) Use a connector for whether to turn ON o... More Details >>

    • No:21094
    • Release Date:2018/08/22 16:25
  • Multiple rating

    By setting the operating condition, such as load level and surrounding air temperature, according to the application, the inverter capacity may be lowered co... More Details >>

    • No:21101
    • Release Date:2018/08/22 16:25
  • Emergency stop of the FR-A800

    For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>

    • No:20860
    • Release Date:2018/08/22 16:24
  • Control power supply

    Turning ON the main circuit power stops the 24 V external power supply operation and enables the normal operation. Therefore, the separate power supply canno... More Details >>

    • No:21018
    • Release Date:2018/08/22 16:25
  • PLC function

    The number of timer points is 16 for the high speed and low speed in total. More Details >>

    • No:21056
    • Release Date:2018/08/22 16:25
  • FR-DU08

    It cannot be connected. When using DU08, connect it to the PU connector. More Details >>

    • No:21111
    • Release Date:2018/08/22 16:25
  • FR-A800 and Ethernet IP communication

    Yes. the options support it. By connecting the following communication option (built-in circuit board) manufactured and sold by HMS to the FR-A800 series, th... More Details >>

    • No:20823
    • Release Date:2018/08/22 16:24
  • Operation mode switch of the FR-A800/F800

    When Pr.551 is set to "3" (Command right to the USB connector at the PU operation), or when the USB is connected, the operation is not switched. More Details >>

    • No:20861
    • Release Date:2018/08/22 16:24

131-140 of Total 144