  • FR-PA07

    Only the operation command source is switched to the FR-A07 and the inverter operation panel does not turn off. (Setting from the inverter operation panel be... More Details >>

    • No:21699
    • Release Date:2018/08/22 16:28
  • PU operation

    The relationship between the acceleration/deceleration reference frequency and acceleration/deceleration time does not change between the PU operation and ex... More Details >>

    • No:21694
    • Release Date:2018/08/22 16:28
  • Advanced magnetic flux vector control

    Yes. Set Pr.89 (Speed control gain) to "0". More Details >>

    • No:21690
    • Release Date:2018/08/22 16:28
  • Frequency setting

    Adjust the terminal 2 bias with Pr.C2 and Pr.C3, and the terminal 2 gain with Pr.125 and Pr.C4. Set Pr.C2 (Terminal 2 frequency setting bias frequency) to 20... More Details >>

    • No:21685
    • Release Date:2018/08/22 16:28
  • Frequency setting

    Since Advanced magnetic flux vector control is chosen, the inverter calculates how much the motor rotation slips from the flowing current and adds the slip a... More Details >>

    • No:21684
    • Release Date:2018/08/22 16:28
  • Terminal

    For an inverter with the terminal AU, use the terminal AU. For other inverters, assign the AU function to an unused terminal. And, short-circuit (turn ON) th... More Details >>

    • No:21678
    • Release Date:2018/08/22 16:28
  • English manual

    On the Mitsubishi Electric FA Global Website, choose "Inverter FREQROL", "Manual", and "FREQROL-E700", and change the language to "English". More Details >>

    • No:21666
    • Release Date:2018/08/22 16:28
  • FR-PA02

    The operation panel FR-PA02 requires the optional FR-E5P (control panel rear cover and adapter set) and connection cable FR-CB20□. Check that Pr.146 (Built-i... More Details >>

    • No:21367
    • Release Date:2018/08/22 16:27
  • UL standard

    Both 200 V class and 400 V class are suitable for use in a circuit capable of delivering not more than 100 kA rms symmetrical amperes, 264 V maximum (528 V f... More Details >>

    • No:21358
    • Release Date:2018/08/22 16:27
  • Operation mode setting

    The stop-on-contact control does not function in the combined operation mode.  Perform the control in the External operation mode. More Details >>

    • No:21354
    • Release Date:2018/08/22 16:27