FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding the default IP address
The default IP address (factory default value) of FX5CPU modules is 192.168.3.250. More Details >>
- No:22290
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:33
-
Regarding how to check MAC Addresses
You can check the MAC address from the name plate on the side of the CPU module or by the Module diagnostics (CPU diagnostics) of GX Works3. More Details >>
- No:39294
- Release Date:2023/02/13 15:37
-
Regarding the latch settings of data register
It is necessary to set the latch range from the following GX Works3 parameters: [Navigation Window] -> [CPU Parameters] -> [Device/Memory Settings] -&... More Details >>
- No:22329
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:04
-
Regarding how to format an SD memory card
In GX Works3, go to Online > CPU Memory Operation, select "SD Memory Card" and execute "Initialization." More Details >>
- No:39344
- Release Date:2023/02/15 10:03
-
Regarding how to update the firmware of the FX5 CPU module
FX5U/FX5UC/FX5UJ CPU modules cannot perform firmware update using GX Works3. Use the SD memory card to update the firmware. However, the FX5S CPU module sup... More Details >>
- No:39325
- Release Date:2023/02/14 09:03
-
Regarding the cause of communication error with GX Works3
From the PC's Internet Protocol Version 4 Properties, uncheck "Obtain an IP address automatically" option and set an arbitrary IP adress that does not dupli... More Details >>
- No:22319
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:38
-
Regarding how to change the IP address
By using the IP address change function, you can change the IP address from a program. More Details >>
- No:39332
- Release Date:2023/02/14 09:09
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
-
Regarding how to Monitor Buffer Memory Values
You can monitor buffer memory values in the Ladder Editor by setting in GX Works3 >Tools >Options > Monitor > Common Item > Monitor Buffer Mem... More Details >>
- No:39324
- Release Date:2023/01/12 16:56
-
Regarding the built-in analog input/output function
FX5U CPU module has 2 built-in voltage input channels (DC0~10V) and 1 built-in voltage output channel (DC0~10V). If an external resister is connected, the m... More Details >>
- No:22313
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:47
1-10 of Total 158