FR-A800-R2R

Are the gain automatically adjusted by the tension PI gain automatic tuning and the one adjusted by speed control P gain compensation the same?
Category : 

Answer

The gain of the tension PI gain automatic tuning is the one of the dancer feedback speed control. The gain adjusted by speed control P gain compensation is the one of the speed control. Thus, they are different.