FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Read and write operations for CC-Link buffer memory
There is no problem in writing/reading data into/from the buffer memory using a FROM/TO instruction with the refresh device setting left blank.The refresh de... More Details >>
- No:23015
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Drive products (servo amplifiers) that can be connected to the FX3U-1PG pulse output block
Servo amplifiers, such as MR-J4-□A and MR-JN-□A, that support pulse train input can be connected. For connectable drive products, such as servo amplifiers, ... More Details >>
- No:24940
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Regarding the COM terminal of the multiple input module
Yes, it's connected internally. More Details >>
- No:39318
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , Analog
-
Regarding cable diversion to FX5-2HC/ES
The cable cannot be used because the connector shape is different, so change the wiring. FX5-2HC/ES is a spring clamp terminal block, and FX3U-2HC is a MIL-... More Details >>
- No:44337
- Release Date:2024/03/20 13:26
- Category: MELSEC iQ-F Series , High-Speed Counter
-
The batch setting of PDO mapping sets the default PDO mapping for all device stations that support PDO mapping. *Note that in the batch setting of PDO mappi... More Details >>
- No:44476
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding TPDO and RPDO allocation
RWr is allocated to TPDO and RWw is allocated to RPDO. More Details >>
- No:44479
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding maximum number of connected stations for built-in CC-Link IE TSN
The maximum number of stations that can be connected in the network depends on the model name of the MX-F model. ・MXF100-16 N32/P32: Up to 46 stations ・MXF... More Details >>
- No:44973
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
- Category: MELSEC MX Controller MX-F Model
-
Regarding connectable Expansion Adapter
The MX-F Model can be connected to iQ-F series Expansion adapters. The following Expansion adapters can be connected. More Details >>
- No:44982
- Release Date:2025/05/08 09:06
- Category: MELSEC MX Controller MX-F Model
-
Regarding iQ-F Series Project Conversion
It's possible. In GX Works3, select [Project] → [Change Module Type/Operation Mode], and select the Series: MX controller, Type/Model: MXF100, Number of Axes... More Details >>
- No:44987
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
- Category: MELSEC-Q Series
111-120 of Total 1123