Follow the procedure below.(1)Eliminate the error cause.(2) Store the error code to be cleared in SD50.(3)Turn OFF and ON SM50.(4) The error is cleared. More Details >>
- No:22613
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Q series device data held in the case of a power failure
The data in the devices assigned to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> [Device Setting] window) is held when a pow... More Details >>
- No:22638
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:37
- Category: MELSEC-Q Series
-
Opening a project in an old version of GX Developer
Products earlier than version 8.58L do not support a project in which the following parameters are set. All the parameters are set to their default values be... More Details >>
- No:22666
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:53
- Category: MELSEC-Q Series
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to check the capacity of the file registers in use
The capacity file registers currently have can be checked in the file register setting section ([PLC Parameter] -> [PLC File] tab). More Details >>
- No:22694
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:19
- Category: MELSEC-Q Series
-
Specifying steps in printing data displayed in the window in GX Works2
GX Works2 Version 1.45X or later supports a print range specifying capability.Set "Start Step" and "End Step" for "Specified Print Range" in the Print window. More Details >>
- No:22695
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Whether or not device indirect specifications in structured ladder programs are allowed
Indirect specifications with "@" cannot be used in structured ladder programs and the Structured Text. Use indirect specifications in a ladder language program. More Details >>
- No:22697
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
There are no settings for deleting the network number and PC number. More Details >>
- No:22708
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
QnA-compatible 3E frame command for built-in Ethernet port in LCPU
The built-in Ethernet port in the L series CPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are ... More Details >>
- No:22726
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Use of 4E frame for built-in Ethernet port of LCPU
The built-in Ethernet port in the L series is compatible only with the QnA-compatible 3E frame. The 4E frame is not supported. More Details >>
- No:22761
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series