FAQ
FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
How to check errors in a CC-Link master station
When an error has occurred in the master station (including the standby master station), the data link control cannot be performed, and you cannot check erro... More Details >>
- No:23078
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
-
PCPU READY complete flag (SM500)
The PCPU READY complete flag (SM500) turns ON when no error is detected in the fixed parameters, servo parameters, and limit switch output data, which are ch... More Details >>
-
Yes. You can check the servo status through the following monitor data. • "[Md.108] Servo status 1" • "[Md.119] Servo status 2" • "[Md.125] Servo status 3... More Details >>
-
Built-in variable analog potentiometers of the FX3G series
D8030 for VR1, and D8031 for VR2. More Details >>
- No:24769
- Release Date:2019/02/27 15:01
- Category: MELSEC-F Series , Main Unit , Analog Control
-
Transferring/editing programs in the previous FX programmable controllers using GX Works2
The earlier series of the FX programmable controllers are compatible with the latest series of the FX programmable controllers. More Details >>
- No:25012
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Programmable controllers with no battery (MELSEC-F)
A battery is used for backing up program memory and latched device data and maintaining clock operation in the event of a power failure. The FX3S/FX3G/FX3G... More Details >>
- No:22259
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Regarding the necessity of using a battery
Device back up is available without using a battery. However, to back up link register (W) and file register (R) devices, a FX3U-32BL (battery) is required.... More Details >>
- No:22296
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:55
- Category: MELSEC iQ-F Series , Option , CPU Module
-
Regarding CW/CCW(Forward pulse/Reverse pulse) output of the built-in positioning function
FX5U/FX5UC/FX5S CPU modules are supported. Up to 2 axes are available in GX Works3 parameter settings. In addition, up to 8 axes can be added by adding a hi... More Details >>
- No:22306
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:48
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
851-860 of Total 1048