Regarding the procedure for functions set in GX Works3
This is possible with the Guidance flow function. On GX Works3, you can view the setting procedure for the function you want to use. *It is supported by GX ... More Details >>
- No:39341
- Release Date:2023/02/14 17:29
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding connection of SD Memory Card module: FX5-SDCD
It can be added in conjunction with an expansion board. For details on how to connect, refer to the following manual. MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC Use... More Details >>
- No:39337
- Release Date:2023/02/14 17:27
- Category: MELSEC iQ-F Series , Option , CPU Module
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding communication data code for SLMP communication
It can not be set for each connection. More Details >>
- No:39312
- Release Date:2023/02/14 08:55
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the driving contacts of high-speed counter instructions
The current value of the high-speed counter is retained and will not be cleared. More Details >>
- No:39304
- Release Date:2023/02/13 16:40
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the number of terminating resistors of FX5-CCL-MS
Two terminating resistors are included. More Details >>
- No:39290
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the simultaneous use of Simple CPU Communication and FX5-CCLGN-MS MELSOFT Connection
Can be used simultaneously. More Details >>
- No:39285
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding error 2440H on CPU module when using FX5-CCLGN-MS
When the power is turned on, the FX5-CCLGN-MS performs parameter check processing, and if an error occurs, the CPU module is also notified of the error. Ther... More Details >>
- No:39282
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>