Data communications between programmable controllers
Any data can be sent and received if the socket communication function instructions are used. More Details >>
- No:22702
- Release Date:2018/09/03 17:29
-
Detecting the connection between a built-in Ethernet port QCPU and hub
You can check the connection to the hub with bit 10 of the special register SD1288. When bit 10 of the SD1288 is on, the QCPU is in connection with the hub. More Details >>
- No:22712
- Release Date:2018/09/03 17:29
-
Make sure to turn off the power of the programmable controller before replacing the battery. Replacing the battery while the power of the programmable con... More Details >>
- No:22509
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:24
-
Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
-
CPU modules supporting the serial communication function
CPU modules supporting the serial communication function are as follows. - Q00UJCPU,Q00UCPU,Q01UCPU - Q02UCPU 10102 or later (with GX Works2 1.15R or l... More Details >>
- No:22530
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:37
-
Compatibility with 64-bit Windows 7
GX Works2 Version 1.62Q or later supports Windows 7. More Details >>
- No:22554
- Release Date:2018/09/03 17:28
-
Necessities for the execution environment of MX Component
Both the developed software and MX Component must be installed. More Details >>
- No:22557
- Release Date:2018/09/03 17:29
- Update:2018/09/20 15:53
-
Battery replacement for universal model QCPU
The contents of the standard RAM and latch devices are not erased if the battery replacement is completed within three minutes, which is the backup power tim... More Details >>
- No:22558
- Release Date:2018/09/03 17:29
-
Connect with a straight cable using a hub. For more details, refer to the following manual. - FL-net (OPCN-2) Interface Module User's Manual More Details >>
- No:22574
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:55
-
Communication between built-in Ethernet port QCPU modules
The following communication methods are available between built-in Ethernet port QCPU modules. - Socket communications are possible. - Communications equ... More Details >>
- No:22586