Dragging and dropping function blocks in a structured project
Function blocks can be dragged and dropped into the program main body of the program block, and become available in the program. More Details >>
- No:22910
- Release Date:2018/09/03 17:30
-
Using devices assigned as local labels in another program (GX Works2)
No.To read from another program, assign the devices as global labels. More Details >>
- No:22863
- Release Date:2018/09/03 17:30
-
Compatibility between GX IEC Developer and GX Developer
GX IEC Developer and GX Developer are different products. They are not compatible. Projects created using GX IEC Developer can neither be opened in GX Develo... More Details >>
- No:22860
- Release Date:2018/09/03 17:30
-
Compatibility between MX Component Version 3 and 4
Applications created using MX Component Version 3 can be used, as they are, on a personal computer on which MX Component Version 4 is installed. MX Component... More Details >>
- No:22839
- Release Date:2018/09/03 17:30
-
Storage media of a project file
The project file written in the write-inhibited media, such as FD, CD-R, or CD-RW, cannot be read. (Condition: The standard Windows status without CD-R/RW w... More Details >>
- No:25007
- Release Date:2019/04/23 11:11
-
Local device comments can be read if the comment file in which the local device comments are stored is written to the CPU module. More Details >>
- No:22869
- Release Date:2018/09/03 17:30
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33
-
Multiplication in the Structured Text
Basic arithmetic operations cannot be performed on unsigned words. Please assign the multiplier to a signed (single/double) word. More Details >>
- No:22886
- Release Date:2018/09/03 17:30
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>