FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
It is possible to apply for single-phase circuit. However, it may be lesseffect in single-phase circuit (100 V, etc) since low voltage circuit is tendedto be... More Details >>
- No:23297
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It means the rated operating voltage (nominal voltage) range andfrequency (when AC operation) of a control coil. More Details >>
- No:23266
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Since it is necessary to energize the pole containing a heater element of athermal load relay, you need to connect it to both side of 3 poles(Between 1/L1-2/... More Details >>
- No:23249
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Standard product of US-N* type has a terminal cover. Moreover, UA-DR1/UA-SH1 driving-unit has a terminal cover as option. More Details >>
- No:23352
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
We have a transparent protective cover of live part for US-H20(DD) to US-H50(DD) that can be installed easily as an optional part. The type nameis UN-CV501US. More Details >>
- No:23347
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
It is a magnetic contactor that can reverse a motor by using two magneticcontactors and switching the connection of their contacts. More Details >>
- No:23287
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Surge voltage occurs due to opening/closing a control coil. Since we donot provide the surge suppressor for a control coil which is available forthem, you ne... More Details >>
- No:23285
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
For US-N/K/H type, since current is opened/closed by semiconductorelement, there is no lifetime related to operating cycles, but werecommend to replace in 10... More Details >>
- No:23274
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
For our reduced-voltage starter, when the starting time is over 15 sec,you need to review the selection of MCS and the wiring between MCD-MCS, and check whet... More Details >>
- No:23267
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a current that can be energized for 8 hours without opening/closingthe magnetic contactor and in the state that the temperature rise value ofeach part ... More Details >>
- No:23255
- Release Date:2018/09/12 15:11
41-50 of Total 142