FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
The Earth Leakaga Circuit Breaker does not work since leakage current ofSSC is the current flowing from the main circuit element to the load sidewhen opening. More Details >>
- No:23338
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
Since the permanent magnet is used for the electromagnet part of SD-Qtype, it is necessary to match its polarity with the polarity of the controlcoil. More Details >>
- No:23324
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to produce with the coil designation of less than AC 230V andDC 220V. Please add " SA" at the end of the type name. More Details >>
- No:23319
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The main circuit of US-N* type applies only AC power supply product. ForDC circuit, US-KD8 type solid state contactor can be used. More Details >>
- No:23314
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is the maximum voltage that opens the contact (turning contact "OFF")when removing the applied voltage of a control coil in a magneticcontactor. More Details >>
- No:23313
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a coil that opens/closes a magnetic contactor by magnetizing(applying suction force) or demagnetizing an electromagnet core. More Details >>
- No:23303
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The contacts are closed by electrical (closing coil) or mechanical operationand even if the operating force is removed, the closed state is maintainedby the ... More Details >>
- No:23253
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a value of voltage which determines the application related to closingcapacity, breaking capacity, opening/closing frequency andopening/closing durabil... More Details >>
- No:23247
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is possible to open/close three-phase load by opening/closing two poleswith three-phase circuit. If US-H opens/closes two poles and theremaining pole is s... More Details >>
- No:23367
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
We do not provide it. More Details >>
- No:23350
- Release Date:2018/09/12 15:12
81-90 of Total 142