FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
There is no polarity in the control coil. More Details >>
- No:23311
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Time rating is 60sec and the rest time is for 2 hours. More Details >>
- No:23308
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>
- No:23304
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is a coil that opens/closes a magnetic contactor by magnetizing(applying suction force) or demagnetizing an electromagnet core. More Details >>
- No:23303
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
There are auxiliary contact (UQ-AX2、UQ-AX2KR) units that can apply forQ11 frame and QR11 frame.1. UQ-AX2 can apply for the left side of Q11 and QR11.2. UQ-AX... More Details >>
- No:23302
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is not possible to detect the voltage variation less than 100msec. More Details >>
- No:23293
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The minimum applicable load voltage and current are as follows. Contactreliability is indicated by fault rate λ60 (Number of faults / Operatingcycles per one... More Details >>
- No:23290
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
If both of a closing coil and a tripping coil are continued to excite at thesame time, it will result in coil burnout. You need to design a system thatdoes n... More Details >>
- No:23282
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
A thermal load relay is intended for burnout protection of three-phasesquirrel cage motor. When direct current is applied to the thermal loadrelay, the opera... More Details >>
- No:23281
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
There is no surge suppressor for a control coil. The control coil of S-T65 toS-N800 type has the AC operation DC excitation method and includes thesurge supp... More Details >>
- No:23276
- Release Date:2018/09/12 15:11
81-90 of Total 142