  • Parameter list

    The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>

    • No:21485
    • Release Date:2018/08/22 16:27
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • Countermeasure against harmonics

    When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>

    • No:21398
    • Release Date:2018/08/22 16:27
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • Tuning

    Setting the tuning data without tuning makes no difference. The tuning method of the FR-A700 is different from that of V500. Tuning can be performed by setti... More Details >>

    • No:21139
    • Release Date:2018/08/22 16:26
  • FR-PA07

    Its protective structure conforms to IP20.Therefore it is not waterproof. More Details >>

    • No:21701
    • Release Date:2018/08/22 16:28
  • Communication option

    You can remove the parameter unit FR-PU02 and install the FR-CU01 there. However, since the interface for the parameter unit is used, the communication speed... More Details >>

    • No:21625
    • Release Date:2018/08/22 16:28
  • Installation dimensions of the heat sink panel through attachment

    The heat sink panel through attachment to the FR-A520-5.5K inverter consist of the top installation frame, bottom installation frame, and upper cover. The to... More Details >>

    • No:21520
    • Release Date:2018/08/22 16:28
  • Number of inverters that can be connected to a 20 A branch circuit breaker

    The basic idea is the same, but the total capacity should be 3.7 kW. (The maximum capacity is also 3.7K.) More Details >>

    • No:21508
    • Release Date:2018/08/22 16:28
  • CC-Link

    The inverters FR-A200 and V200 do not support CC-Link. (The FR-A500 series supports CC-Link.) Use the open collector output and relay output card when combin... More Details >>

    • No:21504
    • Release Date:2018/08/22 16:28