No. the torque cannot be limited by using Pr.9.Set Pr.277 (Stall prevention current switching) to "1".The value of Pr.22 (Stall prevention operation level) w... More Details >>
- No:21766
- Release Date:2018/08/22 16:29
-
The first priority window of the monitor may be set to the current.When the current is displayed on the monitor (the unit is "A"), press "SET" to switch to t... More Details >>
- No:21765
- Release Date:2018/08/22 16:29
-
To set the frequency via CC-Link communication, the NET mode should be selected. The new parameter setting is applied after powering OFF and then ON the inve... More Details >>
- No:21763
- Release Date:2018/08/22 16:29
-
1. Press the PU/EXT key on the operation panel FR-PA07 to choose the PU operation mode. Set Pr.161 (Frequency setting/key lock operation selection) to "1" an... More Details >>
- No:21761
- Release Date:2018/08/22 16:29
-
Set it to "13" (Constant-torque). More Details >>
- No:21752
- Release Date:2018/08/22 16:29
-
Yes. More Details >>
- No:21749
- Release Date:2018/08/22 16:29
-
Turning ON/OFF the output side during operation causes open/close surges that may trigger the protective function (against overcurrent or overvoltage) of the... More Details >>
- No:21725
- Release Date:2018/08/22 16:29
-
The following is the amount of heat generated for each capacity:0.1K: 14W 0.2K: 20W 0.4K: 32W 0.75K: 50W1.5K: 80W 2.2K: 100W 3.7K: 160W 5.5K: 290W7.5K:... More Details >>
- No:21706
- Release Date:2018/08/22 16:29
-
The following is the amount of heat generated for each capacity:0.4K: 40W 0.75K: 55W 1.5K: 90W 2.2K: 100W3.7K: 180W 5.5K: 240W 7.5K: 300W 11K: 400W15K:... More Details >>
- No:21705
- Release Date:2018/08/22 16:29
-
No. The "RUN" key on the FR-PA07 does not work.The start command is accepted from the external source. More Details >>
- No:21703
- Release Date:2018/08/22 16:29