Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
-
Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
-
Regarding the specifications of the built-in Ethernet function of FX5 CPU module
The connection using the Ethernet port can establish a total of 8 connections which includes SLMP, MELSOFT connection, MODBUS/TCP, socket communication, and ... More Details >>
- No:22320
- Release Date:2018/08/30 13:55
- Update:2023/07/04 15:52
-
Regarding the frequency of high-speed counters
The maximum frequency of the FX5U/FX5UC CPU module is 200kHz and the maximum frequency of the FX5S/FX5UJ CPU module is 100 kHz. More Details >>
- No:22312
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:18
-
Regarding address change of positioning operation.
It can be changed. For example, with the positioning instruction, a word device can be assigned to the operand which specifies the positioning address and t... More Details >>
- No:22298
- Release Date:2018/08/30 13:55
- Update:2023/02/14 09:53
-
Regarding the type of Ethernet connection cable
Ethernet standard-compatible cable, category 5 or higher (STP cable) can be used. *Straight cable can be used. When connecting directly to the computer, cr... More Details >>
- No:22295
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:23
-
Regarding the type of battery which can be used with the CPU module.
FX3U-32BL can be used. The battery is not included with the CPU modu... More Details >>
- No:22285
- Release Date:2018/08/30 13:55
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30