- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Network/Communication
FAQ
Keyword Search
FAQ within [ Network/Communication ]
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
-
Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding display of FX5-ENET/IP in a Module configuration Diagram
Please update GX Works3 to the latest version. After updating, FX5-ENET/IP is displayed in the Module configuration diagram of GX Works3. Download the lates... More Details >>
- No:39303
- Release Date:2023/01/12 17:13
-
Regarding setting the FX5 CPU Module that does not support the simple CPU communication function
When connecting 2 FX5 CPU Modules (firmware version 1.110 or later) that support the Simple CPU communication function and 2 FX5 CPU Modules (firmware vers... More Details >>
- No:44329
- Release Date:2024/03/20 13:35
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
-
Reagrding specifying an FTP client domain
The iQ-F series does not support domain specification, so specify the IP address. More Details >>
- No:44359
- Release Date:2024/03/27 15:58
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
-
Regarding the method to connect with multiple devices via Ethernet port
Multiple connections can be established by using a switching hub. More Details >>
- No:22321
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:26
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
-
Regarding handling multiple executions of ADPRW Instructions
When multiple ADPRW instructions are simultaneously executed, communication by the ADPRW command that was executed earlier is completed and communication by ... More Details >>
- No:39354
- Release Date:2023/02/15 10:17