Regarding maintaining device back up
Battery: FX3U-32BL is not required for device back up.The battery is used to store clock data. More Details >>
- No:44976
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding number of expansion adapter connections
The number of expansion adapters varies depending on the type of adapter, and up to six can be connected. ・Analog adapter: Up to 4 ・Communication adapter: ... More Details >>
- No:44966
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Regarding Intelligent Function Modules with connectivity constraints
The following intelligent function modules have restrictions on the number of modules that can be connected. More Details >>
- No:44984
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding use of extended extension cable
Extended extension cable for MX-F Model: FX5-30 EC/FX5-65 EC can be used. However, only one extended extension cable is allowed per system. *Extended extens... More Details >>
- No:44985
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding maximum number of connected stations for built-in CC-Link IE TSN
The maximum number of stations that can be connected in the network depends on the model name of the MX-F model. ・MXF100-16 N32/P32: Up to 46 stations ・MXF... More Details >>
- No:44973
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
- Category: MELSEC MX Controller MX-F Model
-
Regarding number of internal Ethernet port connections
The Ethernet port (P2) has 32 connections. The breakdown is as follows: total of MELSOFT connections, SLMP, and socket communications ≦ 32 connections. Apa... More Details >>
- No:44974
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding the available FB compilation methods
The MX-F Model only supports subroutine type FB. Please note that macro type FB is not supported. More Details >>
- No:44975
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding the built-in positioning function
The MX-F Model also supports the built-in positioning function. The number of control axes is now 4, and PULSE/SIGN and CW/CCW are supported. The maximum f... More Details >>
- No:44978
- Release Date:2025/05/08 09:08
- Category: MELSEC MX Controller MX-F Model
-
Regarding iQ-F Series Project Conversion
It's possible. In GX Works3, select [Project] → [Change Module Type/Operation Mode], and select the Series: MX controller, Type/Model: MXF100, Number of Axes... More Details >>
- No:44987
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Programming is possible with GX Works3. The supported version is 1.115V or later. More Details >>
- No:44962
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model