The hand does not move properly
(Electric operated hand).
    
      The hand does not move properly
The hand operation screen is not displayed on the TB.
(Electric operated hand)
    
  
    - Category : 
 
    - 
      
    
 
  
 
    Answer
  
    Cause:
- Wire breakage on the hand signal line. 
 - The electronic hand controller(manufactured by TAIYO Ltd.) has failed. 
 - Faulty connection in the cables that run between devices. 
 - The software version on the TB and robot controller is not compatible with the electric operated hand. 
 - The user is trying to use the electric operated hand on a model that is not compatible with the electric operated hand. 
 
Measures:
- Check the connections.
 - Check the condition of the hand input/output signal.
 - Check the mating condition of the cables that run between devices.
 - Check whether the software version is compatible or not.
 - Check the model compatibility. 
 
   
    
      
        - Product Name
 
          - Industrial Robots MELFA
 
      
      
        - Series
 
          - FR Series
F Series