In the case of positioning control and OPR control, there are three ways to start positioning:
(1)[cd. 184] Turn on the positioning start signal.
(2)Execute GP.PSTRT instructions.
(3)Turn on the external command signal (CHG).
For starting conditions, refer to the following manual.
MELSEC iQ-F FX5 User's Manual (Positioning Control - Intelligent Function Module)