Cause:The Ethernet cable is not connected surely. There are the device etc. which cause the noise and the noise has applied to the Ethernet cable. Measures:C... More Details >>
- No:23179
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The T/B does not display anything.
Cause:The fuse installed in the controller may have blown out. For the fuse blowout, there may be a ground fault or short circuit in the T/B cable. The T/B m... More Details >>
- No:23180
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
An unusual noise can be heard (from RC).
Cause:A noise is made as the internally mounted fan and its casing resonate. A noise is made by the fan catching internal wiring.Measures:Check the state of ... More Details >>
- No:23168
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The hand does not move properly (air hand).
Cause:An air leak/break in the piping. The solenoid bulb has failed. Wire breakage on the hand signal line. Hand signal line short circuitThe hand IF card ha... More Details >>
- No:23176
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The T/B does not display anything.
Cause:The fuse (4A fuse) installed at the bottom of the 24 V power supply circuit in the controller may have blown out.For the fuse blowout, the emergency st... More Details >>
- No:23184
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The hand does not move properly (Electric operated hand).
Cause:Wire breakage on the hand signal line. The electronic hand controller(manufactured by TAIYO Ltd.) has failed. Faulty connection in the cables that run ... More Details >>
- No:23177
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Cause: AC line inside the controller may have detected the abnormalities. Measures: Check that the primary side’s power supply voltage is being su... More Details >>
- No:23182
- Release Date:2018/09/07 16:09
- Update:2018/10/03 14:52
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Operation panel does not display anything.
Cause:CPU has not started up properly.There is no power supply.An instantaneous power cut exceeding the specification level may have occurred.Measures:Check ... More Details >>
- No:23181
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
Cause:Deterioration in the reducer oil seal. Too much grease was applied. A grease other than the specified grease was applied. Excess grease left on the uni... More Details >>
- No:23174
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot
-
The leakage current breaker trips.
Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>
- No:23173
- Release Date:2018/09/07 16:09
- Category: Vertical type robot , Horizontal type robot , Ceiling mounted, holizontal type robot