  • The tip of the robot is vibrating.

    Cause:The load conditions exceed the specified values(mass, inertia).The load condition settings are not suitable(HNDDAT and WRKDAT settings are not consiste... More Details >>

    • No:23169
    • Release Date:2018/09/07 16:09
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>

    • No:23183
    • Release Date:2018/09/07 16:09
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.[Occurs when operating manually and automatically]•Faulty connection of the cables that run b... More Details >>

    • No:23178
    • Release Date:2018/09/07 16:09
  • Operation panel does not display anything.

    Cause:CPU has not started up properly.There is no power supply.An instantaneous power cut exceeding the specification level may have occurred.Measures:Check ... More Details >>

    • No:23181
    • Release Date:2018/09/07 16:09
  • The position becomes offset.

    Cause:Program error (arithmetic processing, etc.). Teaching operation error. Peripheral equipment is offset. There is a setting error in the origin position ... More Details >>

    • No:23172
    • Release Date:2018/09/07 16:09
  • Oil is leaking.

    Cause:Deterioration in the reducer oil seal. Too much grease was applied. A grease other than the specified grease was applied. Excess grease left on the uni... More Details >>

    • No:23174
    • Release Date:2018/09/07 16:09
  • The servo-on cannot be performed.

    Cause:A servo OFF signal(SRVOFF)is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input and outpu... More Details >>

    • No:23170
    • Release Date:2018/09/07 16:09
  • The leakage current breaker trips.

    Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>

    • No:23173
    • Release Date:2018/09/07 16:09
  • An unusual noise can be heard (from the robot arm).

    Cause:Unusual noises can be caused by friction between movable parts, deformed parts, foreign matters getting inside, and defects in belt tension.An unusual ... More Details >>

    • No:23167
    • Release Date:2018/09/07 16:09
  • The hand does not move properly (Electric operated hand).

    Cause:Wire breakage on the hand signal line. The electronic hand controller(manufactured by TAIYO Ltd.) has failed. Faulty connection in the cables that run ... More Details >>

    • No:23177
    • Release Date:2018/09/07 16:09