Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ Vertical type robot ]

11-18 of Total 18

prev 2 / 2page next
  • The servo-on cannot be performed.

    Cause:A servo OFF signal(SRVOFF)is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input and outpu... More Details >>

    • No:23170
    • Release Date:2018/09/07 16:09
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>

    • No:23183
    • Release Date:2018/09/07 16:09
  • Oil is leaking.

    Cause:Deterioration in the reducer oil seal. Too much grease was applied. A grease other than the specified grease was applied. Excess grease left on the uni... More Details >>

    • No:23174
    • Release Date:2018/09/07 16:09
  • The leakage current breaker trips.

    Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>

    • No:23173
    • Release Date:2018/09/07 16:09
  • The T/B does not display anything.

    Cause:The fuse (4A fuse) installed at the bottom of the 24 V power supply circuit in the controller may have blown out.For the fuse blowout, the emergency st... More Details >>

    • No:23184
    • Release Date:2018/09/07 16:09
  • The T/B does not display anything.

    Cause:The fuse installed in the controller may have blown out. For the fuse blowout, there may be a ground fault or short circuit in the T/B cable. The T/B m... More Details >>

    • No:23180
    • Release Date:2018/09/07 16:09
  • The hand does not move properly (air hand).

    Cause:An air leak/break in the piping. The solenoid bulb has failed. Wire breakage on the hand signal line. Hand signal line short circuitThe hand IF card ha... More Details >>

    • No:23176
    • Release Date:2018/09/07 16:09
  • Breaker trips/overcurrent error occurs.

    Cause:Deterioration in the packing. Scaling on the packing. Using a highly permeable cutting oil. An environment that exceeds the IP functionality. Measures:... More Details >>

    • No:23175
    • Release Date:2018/09/07 16:09

11-18 of Total 18