FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Low-voltage Circuit Breakers
FAQ
Keyword Search
FAQ within [ Low-voltage Circuit Breakers ]
-
A shunt trip (SHT) is an internal accessory which electrically and remotely trips a circuit breaker. When the supply voltage of the SHT is remained between 7... More Details >>
- No:22342
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
Use with 24V, 0.5A or more for AC and DC in normal use. If the breakers are used less than 24V, use with 6V, 1A or more. Moreover, regular inspection of is ... More Details >>
- No:22401
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is a standard equipment (automatic reset type) and 30ms of one-pulse is output at overload tripping. Hold-type circuit is necessary since the output time ... More Details >>
- No:22428
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
Transformers, wires and welded materials may be damaged if an abnormal energization occurs exceeding the energization cycles that are set for the inverter we... More Details >>
- No:22393
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Use in Particular Applications
-
It is the Earth Leakage Circuit Breaker with rated residual operating current of higher than 30mA but not exceeding 1000mA. We provide the products of "100, ... More Details >>
- No:22395
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
It is an earth leakage current (Effective value of residual operating current) which definitely trips Earth Leakage Circuit Breaker and Earth Leakage Relay ... More Details >>
- No:22353
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Inverse time delay operating characteristic
It is a characteristic that operating time inversely become shorter as current increases. For Molded Case Circuit Breakers, protection characteristic meeting... More Details >>
- No:22387
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Ground fault protection (GFR) is prepared as option, it is possible to detect and protect against ground fault current. "Trip" or "Alarm signal output" can b... More Details >>
- No:22412
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
MCB can be used at 85% or less relative humidity and no condensation. More Details >>
- No:24822
- Release Date:2019/04/09 15:11
- Category: Miniature Circuit Breakers
-
It is a method which breaks short circuit current with both upstream and downstream circuit breakers. For example, in the case that short circuit current at ... More Details >>
- No:22357
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
101-110 of Total 123