Shunt Trip for CP30-BA can be provided. However, the pole of that with Shunt Trip is "Relay type" without overcurrent tripping element. Internal circuit is "... More Details >>
- No:22423
- Release Date:2018/08/31 14:33
- Category: Circuit Breakers for Equipment
-
Large electromagnetic force will be generated between conductors/wires due to fault currents. To prevent deformation and breakage of circuit breakers and con... More Details >>
- No:22424
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
"b contact" is normally closed contact, and It is also called "NC (Normally Closed) contact". More Details >>
- No:22435
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
ACB How to store drawout handle
Set the handle holder to the right side of the drawout frame with the included screw and nut, and store the drawout handle. However, the circuit breaker with... More Details >>
- No:22437
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
Default setting of electronic breakers
Each setting knob of the overcurrent trip characteristic is set to the maximum value and then shipped if not specified. However, only the pre-alarm is set to... More Details >>
- No:22438
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Release element in neutral (4P breaker)
AE-SW 4-poles with WS relay (general protection) has overcurrent protection for neutral-pole. The tripping characteristic is same as phase-pole. Moreover, A... More Details >>
- No:22441
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
It is not possible to use standard AE-SW in DC circuit. Special DC use AE-SW is provided if specified. More Details >>
- No:22446
- Release Date:2018/08/31 14:33
- Category: Air Circuit Breakers
-
3P MCCB in 1-phase 2-wire circuit
It is possible. Refer to the figure for connection as below. More Details >>
- No:24811
- Release Date:2019/04/09 15:18
- Category: Molded Case Circuit Breakers
-
degrees of protection to IEC60529
The degess of protection for ACB is IP20 as standard (under the condition that front door is closed). For MCCB and ELCB, the degrees of protection can be IP2... More Details >>
- No:24812
- Release Date:2019/04/09 15:18
- Category: Molded Case Circuit Breakers
-
Plug-in type NF1600-SEW produced
It is impossible. More Details >>
- No:24817
- Release Date:2019/04/09 15:16
- Category: Molded Case Circuit Breakers