FAQ within [ Low-voltage Circuit Breakers ]
-
Change Electronic relay characteristics when it is energized
Only electricians who have enough technical knowledge should change the setting of overcurrent tripping and earth leakage tripping characteristics. Moreover,... More Details >>
- No:22409
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is a button in order to mechanically trip a circuit breaker outside. It is used to confirm switching mechanism at the regular maintenance or sequence-chec... More Details >>
- No:22368
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
The push button is used for testing whether it definitely trips when an earth leakage current occurs. At this test, a Leakage Display button will be come out... More Details >>
- No:22347
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
MCCB stands for "Molded Case Circuit Breaker." This is defined in the IEC standard, IEC 60947-2 and in the UL standard, UL 489. MCB stands for "Miniature Ci... More Details >>
- No:22340
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
The control power supply of the earth leakage detection circuit is taken from the inside of Earth Leakage Circuit Breaker. If used on the secondary side of t... More Details >>
- No:22372
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
degrees of protection to IEC60529
The degess of protection for ACB is IP20 as standard (under the condition that front door is closed). For MCCB and ELCB, the degrees of protection can be IP2... More Details >>
- No:24812
- Release Date:2019/04/09 15:18
- Category: Molded Case Circuit Breakers
-
Short circuit current calculation software
You can calculate that with MELSHORT 2 (Free of charge). More Details >>
- No:22394
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is a tripping zone which instantly trips, when significantly overcurrent such as short-circuit currents flow. More Details >>
- No:22363
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
The circuit breaker is designed to attain a predetermined value of limiting non-actuating time corresponding to a given value of residual current. Our time-d... More Details >>
- No:22351
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Use with 24V, 0.5A or more for AC and DC in normal use. If the breakers are used less than 24V, use with 6V, 1A or more. Moreover, regular inspection of is ... More Details >>
- No:22401
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
1-10 of Total 123