The terminal screw is set in the plastic screw holder and each pole movesone by one. When delivered, the terminal screw is set in the screw holder.When tight... More Details >>
- No:23252
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The main part of SRT(D)-NF type is a special product and different fromthe standard product relay (SR(D)-N type). Therefore, we do not providethe timer unit ... More Details >>
- No:23264
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The functions of 2 and 3 element type are almost same, but since theneutral pole (3/L2, 4/T2) of 3-pole 2-element type is connected inside, itis not possible... More Details >>
- No:23270
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
SD-T12 to T32 and SD-N600, N800 type operation coil terminals have polarity. Connect terminal mumber A1 (+) to the positive and A2 (-) to the negative sid... More Details >>
- No:23271
- Release Date:2018/09/12 15:11
- Update:2021/04/09 16:21
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23278
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since the leakage currents exist in a solid state contactor such as US-N/K/H type even when it is "OFF" state, it can not be used for insulatingload equipmen... More Details >>
- No:23288
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load voltage and current are as follows. Contactreliability is indicated by fault rate λ60 (Number of faults / Operatingcycles per one... More Details >>
- No:23290
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the voltage value used for ordering and represents the ratedoperating voltage. More Details >>
- No:23292
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a circuit that maintains "ON" state even when the "ON" command ofthe control coil disappears by using auxiliary contact "a" of magneticcontactor itself... More Details >>
- No:23295
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a combination of a magnetic contactor and a thermal overload relay. More Details >>
- No:23296