FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
It is not possible to change a contact of SD-Q type. More Details >>
- No:23341
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There is a terminal cover for it. ( In MSOD-Q* type magnetic starter, thereis no terminal cover for the thermal load relay although the contactor parthas a t... More Details >>
- No:23330
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to detect the voltage variation less than 100msec. More Details >>
- No:23293
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There is no surge suppressor for a control coil. The control coil of S-T65 toS-N800 type has the AC operation DC excitation method and includes thesurge supp... More Details >>
- No:23276
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
SD-T12 to T32 and SD-N600, N800 type operation coil terminals have polarity. Connect terminal mumber A1 (+) to the positive and A2 (-) to the negative sid... More Details >>
- No:23271
- Release Date:2018/09/12 15:11
- Update:2021/04/09 16:21
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to apply if the rated operating current value of a magneticcontator is more than the total rated current of motors. However, athermal load rel... More Details >>
- No:23263
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a current value that can break ( turning contact "OFF") under theconditions specified in the standard. (In IEC, number of tests is 50 times) More Details >>
- No:23261
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a circuit flowing large current (several A to approximately 1000A)such as a motor and a lighting circuit, and a main contact (Betweenterminal number 1/... More Details >>
- No:23260
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
This is because the delay time becomes shorter since the rebound force ofa spring against the suction force of a magnetic contactor increases if thecontact "... More Details >>
- No:23309
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
For US-N/K/H type, since current is opened/closed by semiconductorelement, there is no lifetime related to operating cycles, but werecommend to replace in 10... More Details >>
- No:23274
- Release Date:2018/09/12 15:11
- Category: Motor Starters
91-100 of Total 142