SSR stands for "Solid State Relay" and "SSC" stands for "Solid StateContactor". Basically, SSR means the semiconductor relay of smallcapacity 1-pole configur... More Details >>
- No:23246
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Standard product of US-N* type has a terminal cover. Moreover, UA-DR1/UA-SH1 driving-unit has a terminal cover as option. More Details >>
- No:23352
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
We do not provide it. More Details >>
- No:23350
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The withstand voltage of US-H type is 2.5kV. The applied location is asbelow.1. Between a main circuit terminal and a control circuit terminal2. Between all ... More Details >>
- No:23344
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
No.24 terminal with UN-FD4 type "1a"contact can be used for operationsignal of a magnetic contactor and a solid state contactor. More Details >>
- No:23340
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
We can provide "CAN terminal" products for only US-N20?50(TE) type asspecial product.Type name:US-N20?50(TE)CX More Details >>
- No:23337
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
We can not produce it. More Details >>
- No:23332
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The rated impulse withstand voltage of US-H* type is 6KV. This meets therequired impulse characteristic for power distribution equipment specifiedin IEC stan... More Details >>
- No:23329
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since a triac element in UT-SY21 type and UN-SY11/21/31 canopen/close, surge voltage does not occur. Therefore, a coil surgesuppressor is not needed for them. More Details >>