FAQ


FAQAbout Products

- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
The consumption VA of a control circuit is 7VA for AC 100V product and14VA for AC 200 V product. More Details >>
- No:23348
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The Earth Leakaga Circuit Breaker does not work since leakage current ofSSC is the current flowing from the main circuit element to the load sidewhen opening. More Details >>
- No:23338
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the utilization category for opening/closing a heater load ofsemiconductor contactor specified in IEC60947-4-3. Utilization categoryAC-51 applies for "... More Details >>
- No:23318
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It can not be connected in parallel since the characteristics of each US-N/K/H type elements are differenct and the currents are unbalanced whenconnecting in... More Details >>
- No:23317
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a current value that can be closed (turning contact "ON") under theconditions specified in the standards. (In IEC, number of tests is 50times) More Details >>
- No:23294
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the voltage value used for ordering and represents the ratedoperating voltage. More Details >>
- No:23292
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
A thermal load relay is intended for burnout protection of three-phasesquirrel cage motor. When direct current is applied to the thermal loadrelay, the opera... More Details >>
- No:23281
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The faults of main circuit element in a solid state contactor happenbecause:1. Excessive overcurrent that is over permissible current flows due to loadcircui... More Details >>
- No:23258
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to replace it since we do not sell it as a unit. More Details >>
- No:23369
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since US-H* tyep is controlled by DC power supply (12 to 24 V DC), it cannot be operated with AC power supply. More Details >>
- No:23357
- Release Date:2018/09/12 15:12
- Category: Motor Starters
111-120 of Total 142