FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
It is a general starting method that applies full voltage to a motor in orderto start and stop. It is also called Full voltage starting. More Details >>
- No:23256
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The consumption VA of a control circuit is 7VA for AC 100V product and14VA for AC 200 V product. More Details >>
- No:23348
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It stops a motor rapidly by reversing connetion of a contact. More Details >>
- No:23262
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a contactor that opens/close a main contact part by the force ofelectromagnet (coil). More Details >>
- No:23279
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>
- No:23304
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The maximum ambient temparature for US-N/K/H type is 60℃ and theycan not be used with more than 60℃. If the temparature is more than60℃, you need to consider... More Details >>
- No:23346
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When carrying the rated current at ambient temperature of 40℃ (whencarrying the rated heater load), the maximum temparature of cooling finis approximately 100℃. More Details >>
- No:23358
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
For other coil designation, it can be calculated as below.1. For S-T* and S-N* type (AC operation type)(1) Input (Instantaneous, constant) power consumption ... More Details >>
- No:23275
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You can make sure with a display window beside the adjustment knob ofthe thermal load relay. If green is displayed in the display window, it isreset state, a... More Details >>
- No:23251
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The main circuit of US-N* type applies only AC power supply product. ForDC circuit, US-KD8 type solid state contactor can be used. More Details >>
- No:23314
- Release Date:2018/09/12 15:11
- Category: Motor Starters
131-140 of Total 142