You need to connect the two terminal of No.15, 16 or 18 terminal to theload side of the contactor. (The remaining terminal is unnecessary toconnect.) More Details >>
- No:23307
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a circuit flowing small current (A few dozen Ma to several A) such ascontrol coil and indicator light circuit of magnetic contactor and itopens/closes ... More Details >>
- No:23257
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since US-H* tyep is controlled by DC power supply (12 to 24 V DC), it cannot be operated with AC power supply. More Details >>
- No:23357
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Wiring of control circuit will be changed depending on whether the maincircuit voltage and control voltage are the same or different. More Details >>
- No:23356
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the utilization category for opening/closing a motor load ofsemiconductor contactor specified in IEC60947-4-2. Utilization categoryAC-53a applies for "... More Details >>
- No:23345
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to apply for single-phase circuit. However, it may be lesseffect in single-phase circuit (100 V, etc) since low voltage circuit is tendedto be... More Details >>
- No:23297
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a magnetic contactor that can reverse a motor by using two magneticcontactors and switching the connection of their contacts. More Details >>
- No:23287
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Reverse connection is possible (connection of load side terminal as powerside and power side terminal as load side). However, it is necessary toinstall a mag... More Details >>
- No:23286
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is recommended to replace in 10 years or specified number of operatingcycles in the standard. More Details >>
- No:23268
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It means the rated operating voltage (nominal voltage) range andfrequency (when AC operation) of a control coil. More Details >>
- No:23266
- Release Date:2018/09/12 15:11