The rated impulse withstand voltage of US-H* type is 6KV. This meets therequired impulse characteristic for power distribution equipment specifiedin IEC stan... More Details >>
- No:23329
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since the permanent magnet is used for the electromagnet part of SD-Qtype, it is necessary to match its polarity with the polarity of the controlcoil. More Details >>
- No:23324
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to replace it by user. More Details >>
- No:23321
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to produce with the coil designation of less than AC 230V andDC 220V. Please add " SA" at the end of the type name. More Details >>
- No:23319
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the utilization category for opening/closing a heater load ofsemiconductor contactor specified in IEC60947-4-3. Utilization categoryAC-51 applies for "... More Details >>
- No:23318
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It has 1,000 times electrical durability using rated currents. More Details >>
- No:23315
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to install it on the floor. If doing that, the weight of themoving part of a magnetic starter itself acts downward against thetripping spr... More Details >>
- No:23312
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is 1500V 50/60Hz between a terminal and a case for 1 min. More Details >>
- No:23310
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Time rating is 60sec and the rest time is for 2 hours. More Details >>
- No:23308
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load is 20V, 3mA . Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe reliab... More Details >>