FAQAbout Products

- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
It is the utilization category for opening/closing a motor load ofsemiconductor contactor specified in IEC60947-4-2. Utilization categoryAC-53a applies for "... More Details >>
- No:23345
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The terminal screw is set in the plastic screw holder and each pole movesone by one. When delivered, the terminal screw is set in the screw holder.When tight... More Details >>
- No:23252
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the limit of operating cycles that a magnetic contactor can be usedwithout any problems under the conditions specified in the standard. More Details >>
- No:23265
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a contactor that opens/close a main contact part by the force ofelectromagnet (coil). More Details >>
- No:23279
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There are auxiliary contact (UQ-AX2、UQ-AX2KR) units that can apply forQ11 frame and QR11 frame.1. UQ-AX2 can apply for the left side of Q11 and QR11.2. UQ-AX... More Details >>
- No:23302
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
By opening/closing load with SSC of the zero-voltage triggering method, itreduces noise voltage when closing. More Details >>
- No:23323
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Wiring of control circuit will be changed depending on whether the maincircuit voltage and control voltage are the same or different. More Details >>
- No:23356
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since US-H* tyep is controlled by DC power supply (12 to 24 V DC), it cannot be operated with AC power supply. More Details >>
- No:23357
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a value of voltage which determines the application related to closingcapacity, breaking capacity, opening/closing frequency andopening/closing durabil... More Details >>
- No:23247
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since it is necessary to energize the pole containing a heater element of athermal load relay, you need to connect it to both side of 3 poles(Between 1/L1-2/... More Details >>
- No:23249
- Release Date:2018/09/12 15:11