FAQ


FAQAbout Products

- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
There are auxiliary contact (UQ-AX2、UQ-AX2KR) units that can apply forQ11 frame and QR11 frame.1. UQ-AX2 can apply for the left side of Q11 and QR11.2. UQ-AX... More Details >>
- No:23302
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Time rating is 60sec and the rest time is for 2 hours. More Details >>
- No:23308
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is coil capacity (power consumption) when a control coil is energizedand a contact is closed. More Details >>
- No:23333
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
1E is a motor protection relay against overload and constraint such as athermal load relay and an electronic motor protection relay. 2E is a motorprotection ... More Details >>
- No:23245
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is utilization category specified in IEC 60947-4-1. AC-4 category is usedfor inching or plugging etc. More Details >>
- No:23250
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
If both of a closing coil and a tripping coil are continued to excite at thesame time, it will result in coil burnout. You need to design a system thatdoes n... More Details >>
- No:23282
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load voltage and current are as follows. Contactreliability is indicated by fault rate λ60 (Number of faults / Operatingcycles per one... More Details >>
- No:23290
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
SSR stands for "Solid State Relay" and "SSC" stands for "Solid StateContactor". Basically, SSR means the semiconductor relay of smallcapacity 1-pole configur... More Details >>
- No:23246
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It stops a motor rapidly by reversing connetion of a contact. More Details >>
- No:23262
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You need to connect the two terminal of No.15, 16 or 18 terminal to theload side of the contactor. (The remaining terminal is unnecessary toconnect.) More Details >>
- No:23307
- Release Date:2018/09/12 15:11
- Category: Motor Starters
41-50 of Total 142