About Low-voltage Power Distribution Products
We do not provide it. More Details >>
- No:23355
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Wiring of control circuit will be changed depending on whether the maincircuit voltage and control voltage are the same or different. More Details >>
- No:23356
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since US-H* tyep is controlled by DC power supply (12 to 24 V DC), it cannot be operated with AC power supply. More Details >>
- No:23357
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When carrying the rated current at ambient temperature of 40℃ (whencarrying the rated heater load), the maximum temparature of cooling finis approximately 100℃. More Details >>
- No:23358
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When carrying the rated current at ambient temperature of 40℃, themaximum temparature of cooling fin is approximately 90℃. More Details >>
- No:23360
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
US-H* is designed for a heater load ,and a driving-circuit and selection ofa main circuit element are also designed to apply for a heater load andwhen applie... More Details >>
- No:23361
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to add it. More Details >>
- No:23362
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to produce them. More Details >>
- No:23363
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Bearing lifetime of cooling fan is 10,000 to 35,000 hours. However, thelifetime of the cooling fan will be reduced depending on the ambienttemperature rise, ... More Details >>
- No:23364
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
US-N* type can be used for AC power supply motor, heater, lighting loadand capacitor load etc. More Details >>
- No:23365
- Release Date:2018/09/12 15:12
- Category: Motor Starters
51-60 of Total 142