FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
It is recommended to replace in 10 years or specified number of operatingcycles in the standard. More Details >>
- No:23268
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When a motor is overcurrent (overload) due to overload, constraint,phase-loss etc, a thermal load relay prevents motor burnout by heatingand bending a built-... More Details >>
- No:23269
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Inrush current does not flow since the full voltage directly applys theelectromagnet of SD-Q* and only resistance component of theelectromagnet limits the cu... More Details >>
- No:23277
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a circuit that maintains "ON" state even when the "ON" command ofthe control coil disappears by using auxiliary contact "a" of magneticcontactor itself... More Details >>
- No:23295
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since a triac element in UT-SY21 type and UN-SY11/21/31 canopen/close, surge voltage does not occur. Therefore, a coil surgesuppressor is not needed for them. More Details >>
- No:23300
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The rated impulse withstand voltage of US-H* type is 6KV. This meets therequired impulse characteristic for power distribution equipment specifiedin IEC stan... More Details >>
- No:23329
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
We can not produce it. More Details >>
- No:23332
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The maximum ambient temparature for US-N/K/H type is 60℃ and theycan not be used with more than 60℃. If the temparature is more than60℃, you need to consider... More Details >>
- No:23346
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The consumption VA of a control circuit is 7VA for AC 100V product and14VA for AC 200 V product. More Details >>
- No:23348
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to produce, however, it may cause unnecessary trippingwhen using inching. More Details >>
- No:23373
- Release Date:2018/09/12 15:12
- Category: Motor Starters
51-60 of Total 142