No.24 terminal with UN-FD4 type "1a"contact can be used for operationsignal of a magnetic contactor and a solid state contactor. More Details >>
- No:23340
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The head-on type of UN-AX 2 and AX 4 type can be installed. The side-onunit of UN-AX 11 type can not be installed. More Details >>
- No:23342
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Standard product of US-N* type has a terminal cover. Moreover, UA-DR1/UA-SH1 driving-unit has a terminal cover as option. More Details >>
- No:23352
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
US-N* type is controlled by DC power supply (12 to 24 VDC). However,UA-DR1/UA-SH1 driving-unit of option unit make it possible to control byAC power supply (... More Details >>
- No:23359
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Bearing lifetime of cooling fan is 10,000 to 35,000 hours. However, thelifetime of the cooling fan will be reduced depending on the ambienttemperature rise, ... More Details >>
- No:23364
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
In the withstand voltage test, AC 1500V is applied for 1 min However, apressurizing part is only between a terminal part (conductive part) and amounting surf... More Details >>
- No:23377
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Cold start operating characteristic is the operating time from flowingcurrents to operating while a heater temparature of a thermal load relay isthe same as ... More Details >>
- No:23243
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The interlock allows only one magnetic starter to be turned"ON" and notanother opposit side magnetic starter in the case that two magneticstarters must not b... More Details >>
- No:23244
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
RC stands for "Rated current" and the thermal load relay is usedaccording to the rated current (Full load current) of a motor. More Details >>
- No:23254
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23278
- Release Date:2018/09/12 15:11
- Category: Motor Starters