About Low-voltage Power Distribution Products
Since the permanent magnet is used for the electromagnet part of SD-Qtype, it is necessary to match its polarity with the polarity of the controlcoil. More Details >>
- No:23324
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the limit of operating cycles that a magnetic contactor can be usedwithout any problems under the conditions specified in the standard. More Details >>
- No:23265
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The faults of main circuit element in a solid state contactor happenbecause:1. Excessive overcurrent that is over permissible current flows due to loadcircui... More Details >>
- No:23258
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The consumption VA of UA-DR1 type are 200V*0.03A=6VA for AC200Vproduct and 100V*0.03A=3VA for AC100V product. More Details >>
- No:23368
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to open/close three-phase load by opening/closing two poleswith three-phase circuit. If US-H opens/closes two poles and theremaining pole is s... More Details >>
- No:23367
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The Earth Leakaga Circuit Breaker does not work since leakage current ofSSC is the current flowing from the main circuit element to the load sidewhen opening. More Details >>
- No:23338
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You can install it as follows.1. Regular installation of the power supply side terminal as the upper partand the load side terminal as the lower side2. Incli... More Details >>
- No:23283
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The interlock allows only one magnetic starter to be turned"ON" and notanother opposit side magnetic starter in the case that two magneticstarters must not b... More Details >>
- No:23244
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
In the withstand voltage test, 2500V is applied for 1 min. The appliedlocation is as follows.1. Between the conductive part and the grounded metal part, and ... More Details >>
- No:23305
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Since a triac element in UT-SY21 type and UN-SY11/21/31 canopen/close, surge voltage does not occur. Therefore, a coil surgesuppressor is not needed for them. More Details >>