FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
These two different colors of the knob identify 2-element type and 3-element type of a thermal load relay. Gray: TH-* (Heater 2-element type)Orange: TH-*KP t... More Details >>
- No:23273
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The temparature rise of a terminal connected by customer is designed tobe under 65℃ according to the standard. For our products, there is nospecification abo... More Details >>
- No:23259
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The terminal screw is set in the plastic screw holder and each pole movesone by one. When delivered, the terminal screw is set in the screw holder.When tight... More Details >>
- No:23252
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
US-N* type is controlled by DC power supply (12 to 24 VDC). However,UA-DR1/UA-SH1 driving-unit of option unit make it possible to control byAC power supply (... More Details >>
- No:23359
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The maximum ambient temparature for US-N/K/H type is 60℃ and theycan not be used with more than 60℃. If the temparature is more than60℃, you need to consider... More Details >>
- No:23346
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to change a contact of SD-Q type. More Details >>
- No:23341
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the peformance that can energize a main circuit and open/close underthe conditions specified in the standard. More Details >>
- No:23328
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The minimum applicable load is as follows. Contact reliability is indicatedby fault rate λ60 (Number of fault / Operating cycles per one contact) atthe relia... More Details >>
- No:23320
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It has 1,000 times electrical durability using rated currents. More Details >>
- No:23315
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Time rating is 60sec and the rest time is for 2 hours. More Details >>
- No:23308
- Release Date:2018/09/12 15:11
- Category: Motor Starters