FAQ


FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
Cold start operating characteristic is the operating time from flowingcurrents to operating while a heater temparature of a thermal load relay isthe same as ... More Details >>
- No:23243
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
1E is a motor protection relay against overload and constraint such as athermal load relay and an electronic motor protection relay. 2E is a motorprotection ... More Details >>
- No:23245
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
SSR stands for "Solid State Relay" and "SSC" stands for "Solid StateContactor". Basically, SSR means the semiconductor relay of smallcapacity 1-pole configur... More Details >>
- No:23246
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The contacts are closed by electrical (closing coil) or mechanical operationand even if the operating force is removed, the closed state is maintainedby the ... More Details >>
- No:23253
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a current that can be energized for 8 hours without opening/closingthe magnetic contactor and in the state that the temperature rise value ofeach part ... More Details >>
- No:23255
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
When a motor is overcurrent (overload) due to overload, constraint,phase-loss etc, a thermal load relay prevents motor burnout by heatingand bending a built-... More Details >>
- No:23269
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The functions of 2 and 3 element type are almost same, but since theneutral pole (3/L2, 4/T2) of 3-pole 2-element type is connected inside, itis not possible... More Details >>
- No:23270
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
SD-T12 to T32 and SD-N600, N800 type operation coil terminals have polarity. Connect terminal mumber A1 (+) to the positive and A2 (-) to the negative sid... More Details >>
- No:23271
- Release Date:2018/09/12 15:11
- Update:2021/04/09 16:21
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
For other coil designation, it can be calculated as below.1. For S-T* and S-N* type (AC operation type)(1) Input (Instantaneous, constant) power consumption ... More Details >>
- No:23275
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Inrush current does not flow since the full voltage directly applys theelectromagnet of SD-Q* and only resistance component of theelectromagnet limits the cu... More Details >>
- No:23277
- Release Date:2018/09/12 15:11
- Category: Motor Starters
81-90 of Total 142