FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters
FAQ
Keyword Search
Contactors and Motor Starters
FAQ within [ Contactors and Motor Starters ]
-
About Low-voltage Power Distribution Products
It is possible to operate it by using two US-N* type. For the interlock ofboth US-N* type, UA-RE type reversible unit is used. More Details >>
- No:23375
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Bearing lifetime of cooling fan is 10,000 to 35,000 hours. However, thelifetime of the cooling fan will be reduced depending on the ambienttemperature rise, ... More Details >>
- No:23364
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is not possible to replace by customer since the magnetic contactorsused for S-T*DL type and S-N*DL type are different from the standardtype in the specif... More Details >>
- No:23354
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to install them by rotating 90℃ to the right or left from theregular installation except S-N600 and S-N800. It is not possible to rotate180℃ f... More Details >>
- No:23335
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
You can make sure with a display window beside the adjustment knob ofthe thermal load relay. If green is displayed in the display window, it isreset state, a... More Details >>
- No:23251
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
In the withstand voltage test, AC 1500V is applied for 1 min However, apressurizing part is only between a terminal part (conductive part) and amounting surf... More Details >>
- No:23377
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the peformance that open/close under the conditions specified in thestandard without energizing a main circuit. More Details >>
- No:23374
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The consumption VA of UA-DR1 type are 200V*0.03A=6VA for AC200Vproduct and 100V*0.03A=3VA for AC100V product. More Details >>
- No:23368
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is possible to open/close three-phase load by opening/closing two poleswith three-phase circuit. If US-H opens/closes two poles and theremaining pole is s... More Details >>
- No:23367
- Release Date:2018/09/12 15:12
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There is a terminal cover for it. ( In MSOD-Q* type magnetic starter, thereis no terminal cover for the thermal load relay although the contactor parthas a t... More Details >>
- No:23330
- Release Date:2018/09/12 15:11
- Category: Motor Starters