  • MCCB Reverse connection

    Almost MCCBs can be connected n reverse. Check the item column of specification table "reverse connection" in the catalog. If it says "Possible", MCCB can be... More Details >>

    • No:22442
    • Release Date:2018/08/31 14:33
  • IEC60947-2 standard

    IEC 60947-2 is an international standard for circuit breakers. The rated voltage for the applicable circuit breaker is 1000V AC or less, or DC 1500V DC or le... More Details >>

    • No:22361
    • Release Date:2018/08/31 14:33
  • Ambient temperature

    The range of ambient temperature is from -10 to 40 degree Celsius for not only MCCB but also including Earth Leakage Circuit breaker, Earth Leakage Relay and... More Details >>

    • No:22352
    • Release Date:2018/08/31 14:33
  • MCCB 3P4W 3P use

    If switching of neutral pole is not needed, it is possible to use 3-pole MCCB for 3-phase 4- wire circuit. Generally, it is recommended to use 4-pole circuit... More Details >>

    • No:22385
    • Release Date:2018/08/31 14:33
  • Cascade breaking

    It is a method which breaks short circuit current with both upstream and downstream circuit breakers. For example, in the case that short circuit current at ... More Details >>

    • No:22357
    • Release Date:2018/08/31 14:33
  • Interrupting ratings

    A circuit breaker must have interrupting ratings. These are classified as rated short-circuit breaking capacities in IEC 60947-2.e rated ultimate short-circu... More Details >>

    • No:22341
    • Release Date:2018/08/31 14:33
  • Arc space

    It means a space between the edge of a exhaust port and panel component ( such as wall or duct) of a circuit breaker. The arc space is needed for smoothly di... More Details >>

    • No:22373
    • Release Date:2018/08/31 14:33
  • Electronic MCCB 400-1600A How to change rated current and characteristic curve (Except CE breakers)

    First, turn OFF the upstream circuit breaker and the relevant circuit breaker. You must not work in the state where voltage is applied to the relevant circui... More Details >>

    • No:22439
    • Release Date:2018/08/31 14:33
    • Update:2018/08/31 14:35
  • Short circuit current calculation software

    You can calculate that with MELSHORT 2 (Free of charge). More Details >>

    • No:22394
    • Release Date:2018/08/31 14:33
  • Inverse time delay operating characteristic

    It is a characteristic that operating time inversely become shorter as current increases. For Molded Case Circuit Breakers, protection characteristic meeting... More Details >>