FAQ within [ Earth Leakage Circuit Breakers ]

1-10 of Total 21

prev 1 / 3page next
  • High-speed residual operate CBR

    It is Earth Leakage Circuit Breaker that the earth leakage trip operating time at the rated residual operating current (IΔn) is within 0.1 sec, and the earth... More Details >>

    • No:22380
    • Release Date:2018/08/31 14:33
  • ELCB Rated insulation voltage

    It is same as the maximum rated operational voltage. More Details >>

    • No:22365
    • Release Date:2018/08/31 14:33
  • Default setting from the factory

    The knob of the sensitivity current selector is set to the maximum value when shipping in order to prevent unwanted earth leakage tripping when Earth Leakage... More Details >>

    • No:22391
    • Release Date:2018/08/31 14:33
  • ELCB reverse connection

    Almost ELCBs can be connected n reverse. Check the item column of specification table "reverse connection (below 230 V AC)" in the catalog. If it says "Possi... More Details >>

    • No:22434
    • Release Date:2018/08/31 14:33
  • Time-delay CBR

    The circuit breaker is designed to attain a predetermined value of limiting non-actuating time corresponding to a given value of residual current. Our time-d... More Details >>

    • No:22351
    • Release Date:2018/08/31 14:33
  • ELCB installation

    The control power supply of the earth leakage detection circuit is taken from the inside of Earth Leakage Circuit Breaker. If used on the secondary side of t... More Details >>

    • No:22372
    • Release Date:2018/08/31 14:33
  • Time Delay type at the maximum operating time

    The maximum operating time of Time-delay type Earth Leakage Circuit Breaker can be switched to 0.45s, 1.0s and 2.0s. The operating time is:* when it is 0.45s... More Details >>

    • No:22375
    • Release Date:2018/08/31 14:33
  • Earth leakage protective coordination

    Since the total electric circuit length of upstream circuit breaker side is longer than that of downstream circuit breaker, constant earth leakage current b... More Details >>

    • No:22369
    • Release Date:2018/08/31 14:33
  • ELCB High-sensitivity

    It is the Earth Leakage Circuit Breaker with rated residual operating current of 30mA or less. More Details >>

    • No:22390
    • Release Date:2018/08/31 14:33
  • Select rated current sensitivity

    Please select rated current sensitivity ,according to the protection purpose and the protective grounding resistance value of the load equipment. If you alre... More Details >>

    • No:22346
    • Release Date:2018/08/31 14:33