Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ Accessories and Related Components ]

11-20 of Total 21

prev 2 / 3page next
  • Operation handle CE marking

    The operating handle is an external accessory for a circuit breaker and there is no safety standard for the operating handle itself. Therefore, there is no C... More Details >>

    • No:22408
    • Release Date:2018/08/31 14:33
  • Lifetime with SHT or UVT

    The number of trip durability by using SHT and UVT is 10% of the opening/closing number including the number of trips by overcurrent, trip button and test bu... More Details >>

    • No:22407
    • Release Date:2018/08/31 14:33
  • AL/AX/SHT/UVT terminal markings and wire colors

    The color of terminal identification tube and lead wire is same.For one AL switch, 98/ALa terminal : red, 96/ALb terminal : blue, 95/ALc terminal : grayFor S... More Details >>

    • No:22396
    • Release Date:2018/08/31 14:33
  • Type name of the operating handle

    F-2SV is standard, F-2SVE is for emergency use. The difference is the color of the handle and its surroundings parts. More Details >>

    • No:38028
    • Release Date:2021/01/22 17:37
  • SHT

    SHT has a burning prevention switch and it does not burn even if external switch remains "ON" state (After the circuit breaker trips, a burning prevention sw... More Details >>

    • No:22355
    • Release Date:2018/08/31 14:33
  • Micro-load AL and AX switch

    It is possible to produce micro-load AL and AX switch for MCCBs/ELCBs. However, if you need the products compatible with the standards (CE marking product an... More Details >>

    • No:22413
    • Release Date:2018/08/31 14:33
  • EAL

    EAL (Earth Leakage Alarm switch) is a switch that electrically displays tripping state of Earth Leakage Circuit Breaker by eartheleakage/ground fault. EAL do... More Details >>

    • No:22404
    • Release Date:2018/08/31 14:33
  • AL/AX direct connection to PLC

    It is necessary to use AL and AX switches that are suitable for the specification of PLC input unit. Generally AL and AX switch for micro-load are used for i... More Details >>

    • No:22398
    • Release Date:2018/08/31 14:33
  • AL

    AL (Alarm switch) is a switch which electrically displays tripping state of a circuit breaker.The markings of the switch are 8/ALa, 96/ALb and 95/ALc.*When t... More Details >>

    • No:22350
    • Release Date:2018/08/31 14:33
  • PAL(Pre-Alarm Module)

    Pre-Alarm is a function which outputs an alarm if the load current exceeds setting current value. This is useful for securing continuous power supply and pre... More Details >>

    • No:22376
    • Release Date:2018/08/31 14:33

11-20 of Total 21

Inquiries